17 Mart 2020 Salı

Types of Energy Meter and their working Principles



Energy meter is an instrument which measures amount of electrical energy used by the consumers. Utilities install these instruments at every place like homes, industries, organizations to charge the electricity consumption by loads such as lights, fans and other appliances. When energy savings during certain periods are desired, some meters may measure demand, the maximum use of power in some interval.
“Time of day” metering allows electric rates to be changed during a day, to record usage during peak high-cost periods and off-peak, lower-cost, periods. Also, in some areas meters have relays for demand response load shedding during peak load periods.Most interesting type are used as prepaid electricity meters.
Types of energy meter are given below with explanation Basic unit of power is watts. One thousand watts is one kilowatt. If we use one kilowatt in one hour, it is considered as one unit of energy consumed.
These meters measure the instantaneous voltage and currents, calculate its product and gives instantaneous power. This power is integrated over a period which gives the energy utilized over that time period. Energy meter are classified in three basic types accordance with various factors such as: 1.
Type of display 2. Technical like single phase, LT, three phases, HT and many more. 3.
Type of Usage like domestic, commercial and industrial 4. Type of metering point According to construction energy meter classified into three types which are given below. According to phase energy meter classified into three types which are given below.
1. Single Phase Energy Meter 2. Three Phase Energy Meter Electronic meters display the energy used on an LCD or LED display, and some can also transmit readings to remote places.
In addition to measuring energy used, electronic meters can also record other parameters of the load and supply such as instantaneous and maximum rate of usage demands, voltages, power factor and reactive power used etc. They can also support time-of-day billing, for example, recording the amount of energy used during on-peak and off-peak hours. These are of accurate, high procession and reliable types of measuring instruments as compared to conventional mechanical meters.
It consumes less power and starts measuring instantaneously when connected to load. These meters might be analog or digital. In analog meters, power is converted to proportional frequency or pulse rate and it is integrated by counters placed inside it.
In digital electric meter power is directly measured by high end processor. The power is integrated by logic circuits to get the energy and also for testing and calibration purpose. It is then converted to frequency or pulse rate.
➢ Digital Electronic Energy Meter: Digital signal processor or high performance microprocessors are used in digital electric meters. Similar to the analog meters, voltage and current transducers are connected to a high resolution ADC. Once it converts analog signals to digital samples, voltage and current samples are multiplied and integrated by digital circuits to measure the energy consumed.
Microprocessor also calculates phase angle between voltage and current, so that it also measures and indicates reactive power. It is programmed in such a way that it calculates energy according to the tariff and other parameters like power factor, maximum demand, etc and stores all these values in a non volatile memory EEPROM. It contains real time clock (RTC) for calculating time for power integration, maximum demand calculations and also date and time stamps for particular parameters.
Furthermore it interacts with liquid crystal display (LCD), communication devices and other meter outputs. Battery is provided for RTC and other significant peripherals for backup power. A smart meter is an electronic device that records consumption of electric energy and communicates the information to the electricity supplier for monitoring and billing.
Smart meters typically record energy hourly or more frequently, and report at least daily. Smart meters enable two-way communication between the meter and the central system. Such an advanced metering infrastructure (AMI) differs from automatic meter reading (AMR) in that it enables two-way communication between the meter and the supplier.
Communications from the meter to the network may be wireless, or via fixed wired connections such as power line carrier (PLC). Wireless communication options in common use include cellular communications (which can be expensive), Wi-Fi (readily available), wireless ad hoc networks over Wi-Fi, wireless mesh networks, low power long range wireless (LoRa), ZigBee (low power, low data rate wireless), and Wi-SUN (Smart Utility Networks). It is an advanced metering technology involving placing intelligent meters to read, process and feedback the data to customers.
It measures energy consumption, remotely switches the supply to customers and remotely controls the maximum electricity consumption. Smart metering system uses the advanced metering infrastructure system technology for better performance. These are capable of communicating in both directions.
They can transmit the data to the utilities like energy consumption, parameter values, alarms, etc and also can receive information from utilities such as automatic meter reading system, reconnect/disconnect instructions, upgrading of meter software’s and other important messages. These meters reduce the need to visit while taking or reading monthly bill. Modems are used in these smart meters to facilitate communication systems such as telephone, wireless, fiber cable, power line communications.
Another advantage of smart metering is complete avoidance of tampering of energy meter where there is scope of using power in an illegal way. Read for more about  Energy Meters.

What is Switch Gear? And its main Function in Electrical System



The apparatus used for controlling, regulating and switching on or off the electrical circuit in the electrical power system is known as strong. It also includes the combination of switching devices with associated control, measuring, protecting and regulating equipment. The switch gear devices and their assemblies are used in connection with the generation, transmission, distribution, and conversion of electrical energy.
We all are familiar with low voltage switches and re-wireable fuses in our homes. Switches are used for opening and closing an electric circuit while fuses are used for over-current and short circuit protection. In such a way, every electrical device wants a switching and a protecting device.
Various forms of switching and protective devices have been developed. Thus, switch gear can be taken as a general term covering a wide range of equipment concerned with the switching, protection, and control of various electrical equipment. :• Electrical protection • Electrical isolation of sections of an installation • Local or remote switching The aim is to avoid or to limit the destructive or dangerous consequences of excessive (short circuit) currents, or those due to overloading and insulation failure, and to separate the defective circuit from the rest of the installation.
A distinction is made between the protection of: • The elements of the installation (cables, wires, switch gear…) • Equipment and appliances supplied from the installation The protection of circuits • Against overload; a condition of excessive current being drawn from a healthy (unfaulted) installation. • Against short-circuit currents due to complete failure of insulation between conductors of different phases or (in TN systems) between a phase and neutral (or PE) conductor. Protection in these cases is provided either by fuses or circuit-breaker, in the distribution board at the origin of the final circuit (i.
e. the circuit to which the load is connected). The protection of persons • Against insulation failures.
According to the system of earthing for the installation (TN, TT or IT) the protection will be provided by fuses or circuit-breakers, residual current devices, and/or permanent monitoring of the insulation resistance of the installation to earth. The protection of electric motors • Against overheating, due, for example, to long term overloading, stalled rotor, single-phasing, etc. Thermal relays, specially designed to match the particular characteristics of motors are used.
Such relays may, if required, also protect the motor-circuit cable against overload. Short-circuit protection is provided either by type aM fuses or by a circuit-breaker from which the thermal (overload) protective element has been removed, or otherwise made inoperative. The aim of isolation is to separate a circuit or apparatus (such as a motor, etc.
) from the remainder of a system which is energized, in order that personnel may carry out work on the isolated part in perfect safety. An isolating device must fulfill the following requirements: • All poles of a circuit, including the neutral (except where the neutral is a PEN conductor) must open. • It must be provided with a locking system in open position with a key (e.
g. by means of a padlock) in order to avoid an unauthorized reclosure by inadvertence • It must comply with a recognized national or international standard (e.g.
IEC 60947-3) concerning clearance between contacts, creepage distances, over voltage withstand capability, etc. In broad terms “control” signifies any facility for safely modifying a load-carrying power system at all levels of an installation. The operation of switchgear is an important part of power-system control.
Functional control This control relates to all switching operations in normal service conditions for energizing or de-energizing a part of a system or installation, or an individual piece of equipment, item of plant, etc. Switch gear intended for such duty must be installed at least: • At the origin of any installation • At the final load circuit or circuits (one switch may control several loads) Emergency switching – emergency stop An emergency switching is intended to de-energize a live circuit which is, or could become, dangerous (electric shock or fire). An emergency stop is intended to halt a movement which has become dangerous.
• The emergency control device or its means of operation (local or at remote location(s)) such as a large red mushroom-headed emergency-stop push button must be recognizable and readily accessible, in proximity to any position at which danger could arise or be seen. • A single action must result in a complete switching-off of all live conductors • A “break glass” emergency switching initiation device is authorized, but in unmanned installations the re-energizing of the circuit can only be achieved by means of a key held by an authorized person. It should be noted that in certain cases, an emergency system of braking, may require that the auxiliary supply to the braking-system circuits be maintained until final stoppage of the machinery.
Switching-off for mechanical maintenance work This operation assures the stopping of a machine and its impossibility to be inadvertent restarted while mechanical maintenance work is being carried out on the driven machinery. The shutdown is generally carried out at the functional switching device, with the use of a suitable safety lock and warning notice at the switch mechanism. Read more about  Switch Gears.