17 Mart 2020 Salı

Types of Energy Meter and their working Principles



Energy meter is an instrument which measures amount of electrical energy used by the consumers. Utilities install these instruments at every place like homes, industries, organizations to charge the electricity consumption by loads such as lights, fans and other appliances. When energy savings during certain periods are desired, some meters may measure demand, the maximum use of power in some interval.
“Time of day” metering allows electric rates to be changed during a day, to record usage during peak high-cost periods and off-peak, lower-cost, periods. Also, in some areas meters have relays for demand response load shedding during peak load periods.Most interesting type are used as prepaid electricity meters.
Types of energy meter are given below with explanation Basic unit of power is watts. One thousand watts is one kilowatt. If we use one kilowatt in one hour, it is considered as one unit of energy consumed.
These meters measure the instantaneous voltage and currents, calculate its product and gives instantaneous power. This power is integrated over a period which gives the energy utilized over that time period. Energy meter are classified in three basic types accordance with various factors such as: 1.
Type of display 2. Technical like single phase, LT, three phases, HT and many more. 3.
Type of Usage like domestic, commercial and industrial 4. Type of metering point According to construction energy meter classified into three types which are given below. According to phase energy meter classified into three types which are given below.
1. Single Phase Energy Meter 2. Three Phase Energy Meter Electronic meters display the energy used on an LCD or LED display, and some can also transmit readings to remote places.
In addition to measuring energy used, electronic meters can also record other parameters of the load and supply such as instantaneous and maximum rate of usage demands, voltages, power factor and reactive power used etc. They can also support time-of-day billing, for example, recording the amount of energy used during on-peak and off-peak hours. These are of accurate, high procession and reliable types of measuring instruments as compared to conventional mechanical meters.
It consumes less power and starts measuring instantaneously when connected to load. These meters might be analog or digital. In analog meters, power is converted to proportional frequency or pulse rate and it is integrated by counters placed inside it.
In digital electric meter power is directly measured by high end processor. The power is integrated by logic circuits to get the energy and also for testing and calibration purpose. It is then converted to frequency or pulse rate.
➢ Digital Electronic Energy Meter: Digital signal processor or high performance microprocessors are used in digital electric meters. Similar to the analog meters, voltage and current transducers are connected to a high resolution ADC. Once it converts analog signals to digital samples, voltage and current samples are multiplied and integrated by digital circuits to measure the energy consumed.
Microprocessor also calculates phase angle between voltage and current, so that it also measures and indicates reactive power. It is programmed in such a way that it calculates energy according to the tariff and other parameters like power factor, maximum demand, etc and stores all these values in a non volatile memory EEPROM. It contains real time clock (RTC) for calculating time for power integration, maximum demand calculations and also date and time stamps for particular parameters.
Furthermore it interacts with liquid crystal display (LCD), communication devices and other meter outputs. Battery is provided for RTC and other significant peripherals for backup power. A smart meter is an electronic device that records consumption of electric energy and communicates the information to the electricity supplier for monitoring and billing.
Smart meters typically record energy hourly or more frequently, and report at least daily. Smart meters enable two-way communication between the meter and the central system. Such an advanced metering infrastructure (AMI) differs from automatic meter reading (AMR) in that it enables two-way communication between the meter and the supplier.
Communications from the meter to the network may be wireless, or via fixed wired connections such as power line carrier (PLC). Wireless communication options in common use include cellular communications (which can be expensive), Wi-Fi (readily available), wireless ad hoc networks over Wi-Fi, wireless mesh networks, low power long range wireless (LoRa), ZigBee (low power, low data rate wireless), and Wi-SUN (Smart Utility Networks). It is an advanced metering technology involving placing intelligent meters to read, process and feedback the data to customers.
It measures energy consumption, remotely switches the supply to customers and remotely controls the maximum electricity consumption. Smart metering system uses the advanced metering infrastructure system technology for better performance. These are capable of communicating in both directions.
They can transmit the data to the utilities like energy consumption, parameter values, alarms, etc and also can receive information from utilities such as automatic meter reading system, reconnect/disconnect instructions, upgrading of meter software’s and other important messages. These meters reduce the need to visit while taking or reading monthly bill. Modems are used in these smart meters to facilitate communication systems such as telephone, wireless, fiber cable, power line communications.
Another advantage of smart metering is complete avoidance of tampering of energy meter where there is scope of using power in an illegal way. Read for more about  Energy Meters.

What is Switch Gear? And its main Function in Electrical System



The apparatus used for controlling, regulating and switching on or off the electrical circuit in the electrical power system is known as strong. It also includes the combination of switching devices with associated control, measuring, protecting and regulating equipment. The switch gear devices and their assemblies are used in connection with the generation, transmission, distribution, and conversion of electrical energy.
We all are familiar with low voltage switches and re-wireable fuses in our homes. Switches are used for opening and closing an electric circuit while fuses are used for over-current and short circuit protection. In such a way, every electrical device wants a switching and a protecting device.
Various forms of switching and protective devices have been developed. Thus, switch gear can be taken as a general term covering a wide range of equipment concerned with the switching, protection, and control of various electrical equipment. :• Electrical protection • Electrical isolation of sections of an installation • Local or remote switching The aim is to avoid or to limit the destructive or dangerous consequences of excessive (short circuit) currents, or those due to overloading and insulation failure, and to separate the defective circuit from the rest of the installation.
A distinction is made between the protection of: • The elements of the installation (cables, wires, switch gear…) • Equipment and appliances supplied from the installation The protection of circuits • Against overload; a condition of excessive current being drawn from a healthy (unfaulted) installation. • Against short-circuit currents due to complete failure of insulation between conductors of different phases or (in TN systems) between a phase and neutral (or PE) conductor. Protection in these cases is provided either by fuses or circuit-breaker, in the distribution board at the origin of the final circuit (i.
e. the circuit to which the load is connected). The protection of persons • Against insulation failures.
According to the system of earthing for the installation (TN, TT or IT) the protection will be provided by fuses or circuit-breakers, residual current devices, and/or permanent monitoring of the insulation resistance of the installation to earth. The protection of electric motors • Against overheating, due, for example, to long term overloading, stalled rotor, single-phasing, etc. Thermal relays, specially designed to match the particular characteristics of motors are used.
Such relays may, if required, also protect the motor-circuit cable against overload. Short-circuit protection is provided either by type aM fuses or by a circuit-breaker from which the thermal (overload) protective element has been removed, or otherwise made inoperative. The aim of isolation is to separate a circuit or apparatus (such as a motor, etc.
) from the remainder of a system which is energized, in order that personnel may carry out work on the isolated part in perfect safety. An isolating device must fulfill the following requirements: • All poles of a circuit, including the neutral (except where the neutral is a PEN conductor) must open. • It must be provided with a locking system in open position with a key (e.
g. by means of a padlock) in order to avoid an unauthorized reclosure by inadvertence • It must comply with a recognized national or international standard (e.g.
IEC 60947-3) concerning clearance between contacts, creepage distances, over voltage withstand capability, etc. In broad terms “control” signifies any facility for safely modifying a load-carrying power system at all levels of an installation. The operation of switchgear is an important part of power-system control.
Functional control This control relates to all switching operations in normal service conditions for energizing or de-energizing a part of a system or installation, or an individual piece of equipment, item of plant, etc. Switch gear intended for such duty must be installed at least: • At the origin of any installation • At the final load circuit or circuits (one switch may control several loads) Emergency switching – emergency stop An emergency switching is intended to de-energize a live circuit which is, or could become, dangerous (electric shock or fire). An emergency stop is intended to halt a movement which has become dangerous.
• The emergency control device or its means of operation (local or at remote location(s)) such as a large red mushroom-headed emergency-stop push button must be recognizable and readily accessible, in proximity to any position at which danger could arise or be seen. • A single action must result in a complete switching-off of all live conductors • A “break glass” emergency switching initiation device is authorized, but in unmanned installations the re-energizing of the circuit can only be achieved by means of a key held by an authorized person. It should be noted that in certain cases, an emergency system of braking, may require that the auxiliary supply to the braking-system circuits be maintained until final stoppage of the machinery.
Switching-off for mechanical maintenance work This operation assures the stopping of a machine and its impossibility to be inadvertent restarted while mechanical maintenance work is being carried out on the driven machinery. The shutdown is generally carried out at the functional switching device, with the use of a suitable safety lock and warning notice at the switch mechanism. Read more about  Switch Gears.

21 Ocak 2020 Salı

Solar Panels and Difference Between Monocrystalline and Polycrystalline



b absorb sunlight as a source of energy to generate direct current electricity. A photovoltaic (PV) module is a packaged, connected assembly of photovoltaic solar cells available in different voltages and wattages. Photovoltaic modules constitute the photovoltaic array of a photovoltaic system that generates and supplies solar electricity in commercial and residential applications. Difference Between Monocrystalline and Polycrystalline Solar Panels are given below with advantages and advantages of both types. The mono-crystalline solar panels cells are also known as single crystalline cells. They are incredibly easy to identify because they are a dark black in colour. Mono-crystalline cells are made from an incredibly pure form of silicon, which makes them the most efficient material for the conversion of sunlight into energy. Additionally, mono-crystalline cells are also the most space-efficient form of silicon solar cell. They also have the advantage of being the ones that last the longest out of all the silicon-based solar cells. In fact, many manufacturers will offer warranties of up to 25 years on this type of system – a warranty that lasts half of their expected life. However, while these systems are superior, they do come at quite a hefty price. Mono-crystalline cells are the most expensive option out of all of the silicon solar cell types, mostly because the four-sided cutting system results in a large amount of waste. Poly-crystalline acts as a cheaper alternative. The polycrystalline solar cells are also known as polysilicon and multi-silicon cells. They were the first solar cells to be developed when the industry started in the 1980s. Most interestingly, polycrystalline cells do not undergo the same cutting process as the monocrystalline cells. Instead, the silicon is melted and then poured into a square mould. This is what creates the specific shape of the polycrystalline. One of the benefits of this process is that the solar cells become much more affordable. This is because hardly any silicon is wasted during the manufacturing process. However, they are less efficient than monocrystalline solar cells, and also require a lot more space. This is due to the fact that they have lower levels of purity than the single crystalline cell models. Poly-crystalline also has a lower tolerance for heat than mono-crystalline. This means that they are unable to function as efficiently in high temperatures. This can be a massive disadvantage in areas with hot climates.

14 Ocak 2020 Salı

What is Synchronous Machine and Its Basic Working Principle



Electrical motor in general is an electro-mechanical device that converts energy from electrical domain to mechanical domain. Based on the type of input we have classified it into single phase and 3 phase motors. Among 3 phase motors, induction motors and synchronous machine are more widely used. When a 3 phase electric conductors are placed in a certain geometrical positions (In certain angle from one another) then an electrical field is generated. Now the rotating magnetic field rotates at a certain speed, that speed is called synchronous speed. Now if an electromagnet is present in this rotating magnetic field, the electromagnet is magnetically locked with this rotating magnetic field and rotates with same speed of rotating field. Synchronous motors is called so because the speed of the rotor of this motor is same as the rotating magnetic field. It is basically a fixed speed motor because it has only one speed, which is synchronous speed and therefore no intermediate speed is there or in other words it’s in synchronism with the supply frequency. Synchronous motors are available in b sub-fractional horsepower sizes  to high power industrial sizes.In the fractional horsepower range, most synchronous motors are used where precise constant speed is required. These machines are commonly used in analog electric clocks, timers and other devices where correct time is required. In higher power industrial sizes, the synchronous motor provides two important functions. First, it is a highly efficient means of converting AC energy to work. Second, it can operate at leading or unity power factor and thereby provide power-factor correction. The synchronous speed of a synchronous motor is given: in rpm, by: and in rad·s−1 , by: If is the number of pole pairs per phase (rarely, planes of commutation) instead, simply divide both formulas by 2. where f = supply frequency & p = no. of poles Synchronous motor is a doubly excited machine i.e two electrical inputs are provided to it. It’s stator winding which consists of a 3 phase winding is provided with 3 phase supply and rotor is provided with DC supply. The 3 phase stator winding carrying 3 phase currents produces 3 phase rotating magnetic flux. The rotor carrying DC supply also produces a constant flux.

Difference between Synchronous and Induction Motor



Both synchronous and induction machines work on AC supply, ie; they are AC machines. For AC machines, the basic requirement is to create a rotational magnetic field so that the rotor can rotate, and energy can be obtained. (mechanical for motor, electrical for alternator) Now, the difference between a synchronous machine and an induction machine is based on how the rotational magnetic field is utilized. The three phase supply, when given to the stator windings, creates a rotating magnetic field. Now, the rotor of an induction machine is a group of short circuited windings where the rotating magnetic field is to act. The underlying principle is electromagnetic induction, similar to transformers – the rotor gets an induced current, that means – a current carrying loop inside the magnetic field. This makes the rotor rotate. But, if both rotating magnetic field and rotor rotate in the same synchronous speed, there will be no induced EMF inside the rotor, because the field will be then constant w.r.t the rotor, and for rotation, change in flux should be there. Thus, the rotation happens with a “slip” between the rotor and the stator. The slip refers to the inability of the rotor to catch up with the (speed of) rotating stator magnetic field. Thus rotor will rotate, and output is obtained, if there is slip between the rotor and stator magnetic field. This is the principle of working of an induction machine. Now, consider am utilizing the rotating magnetic field by making an electromagnet rotate as a rotor , which is fed with a DC supply. In such a case, the machine will run in synchronous speed, and this machine is called a iHowever, it is to be noted that due to inertia of the rotor, the rotor electromagnet cannot immediately respond to the rotating magnetic field. This means that the synchronous machine does not start by itself. To provide the starting torque, additional winding called “i” is provided in rotor, which make the synchronous machine similar to an induction machine during starting. As the machine starts, the rotor naturally locks up with the rotating magnetic field and rotates in synchronous speed. This means that during normal running conditions, the damper winding will carry no current. (Similar to the rotor winding in an induction machine at synchronous speed) Differences: Here are the few Differences between Synchronous and Induction Motor

Synchronous Motors Main Features and their Applications



Electrical motor in general is an electro-mechanical device that converts energy from electrical domain to mechanical domain.A b is an AC motor in which, at steady state, [1]  the rotation of the shaft is synchronized with the frequency of the supply current; the rotation period is exactly equal to an integral number of AC cycles. Synchronous motors contain multiphase AC electromagnets on the stator of the motor that create a magnetic field which rotates in time with the oscillations of the line current. The rotor with permanent magnets or electromagnets turns in step with the stator field at the same rate and as a result, provides the second synchronized rotating magnet field of any AC motor. A synchronous motor is termed doubly fed if it is supplied with independently excited multiphase AC electromagnets on both the rotor and stator Based on the type of input we have classified it into single phase and 3 phase motors. Synchronous motors are more widely used in industrial Some of the main features of synchronous motor are as follows:- 1. Synchronous motors are inherently not self starting. 2. They require some external means to bring their speed close to synchronous speed to before they are synchronized. strong The speed of operation of is in synchronism with the supply frequency. strong At supply frequency is constant they behave as constant speed motor irrespective of load condition. 5. This motor has the unique characteristics of operating under any electrical power factor. This makes it used in electrical for power factor improvement. 1. As synchronous motor is capable of operating under either leading and lagging power factor, it can be used for power factor improvement.  A synchronous motor under no-load have leading power factor. It is used in power system in place of static capacitors. 2. Synchronous motor is used where high power at low speed required. Such as rolling mills, chippers, mixers, pumps, pumps, compressor etc.

Energy meter of Electromechanical inductionType and Its working Principle



An electricity meter, electric meter, electrical meter, or energy meter is a device that measures the amount of electric energy consumed by a residence, a business, or an electrically powered device. It is the popularly known and most common type of age old watt hour meter. It consists of rotating aluminum disc mounted on a spindle between two electro-magnets. Speed of rotation of disc is proportional to the power and this power is integrated by the use of counter mechanism and gear trains in. It comprises of two silicon steel laminated electromagnets i.e., series and shunt magnets. Series magnet carries a coil which is of few turns of thick wire connected in series with line whereas shunt magnet carries coil with many turns of thin wire connected across the supply. Breaking magnet is a permanent magnet which applies the force opposite to normal disc rotation to move that disc at balanced position and to stop the disc while power is off. The working of single phase induction type energy meters are based on two main fundamentals: i.  Rotation of aluminum disk. ii.  Arrangement of counting and displaying the amount of energy consumed. Rotation of an Aluminum Disk: The rotation of metallic disk is operated by two coils. Both the coils are arranged in such way that one coil produces a magnetic field in proportion to voltage and the other coil creates a magnetic field proportion to current. The field produced by voltage coil is delayed by 90° so that eddy current is induced in the disk. The force exerted on the disk by the two fields is proportional to the product of the immediate current and voltage in the coils. As a result of it, a lite weight aluminum disk rotates in an air gap. But there is a need to stop a disk when there is no power supply. A permanent magnet works as a brake which opposes the rotation of the disk and balances the speed of rotation with respect to power consumption. Arrangement of Counting and Displaying the Energy Consumed: In this system, the rotation of the floating disk has been counted and then displayed on the meter window. The aluminum disk is connected to a spindle which has a gear. This gear drives the register and the revolution of the disk has been counted and displayed on the register which has series of dials and each dial represent a single digit. There is a small display window in the front of the meter which displays the reading of energy consumed with the help of dials. There is a copper shading ring at the central limb of the shunt magnet. To make the phase angle between flux produced by shunt magnet and supply voltage about 900, small adjustments in the place of the ring is required. Read for more about Energy Meters